APDU10150SW APC NetShelter Rack PDU Advanced, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet

[wpcode id=”1445976″][/wpcode]

1,735.43$ex. VAT

Manufacturer

Condition: New
GTIN: 0731304439660

2 pcs in stock
Delivery: 1 - 4 days

SKU: APDU10150SW Categories: ,

Trade Account

WhatsApp

Online support

[rev_slider slidertitle=”single products page banner” alias=”slider-home-desktops-12″]

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded by breaker to simplify deployment. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today’s high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.



Specifications

PDU typesSwitched
Rack capacity0U
AC outlets quantity40 AC outlet(s)
Power plugIEC 60309
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Nominal input voltage230 V
Maximum current32 A
Maximum power7360 W


Specifications

PDU typesSwitched
Rack capacity0U
AC outlets quantity40 AC outlet(s)
Power plugIEC 60309
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Nominal input voltage230 V
Maximum current32 A
Maximum power7360 W