Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes .
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Audible alarms
Provides notification of changing utility power and UPS power conditions
LED status display
Quickly understand unit and power status with visual indicators.
Specifications
UPS topology | Line-Interactive |
Output power capacity | 0.5 kVA |
Output power | 300 W |
Waveform | Sine |
Input operation voltage (min) | 140 V |
Input operation voltage (max) | 300 V |
Input frequency | 50/60 Hz |
Output frequency | 50/60 Hz |
Automatic Voltage Regulation (AVR) | Y |
Surge energy rating | 273 J |
Efficiency | 96.1% |
Input power factor | 0.63 |
Noise level | 40 dB |
Surge protection | Y |
Audible alarm(s) | Y |
Audible alarm modes | Alarm when on battery, Low battery alarm |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
AC outlets quantity | 3 AC outlet(s) |
Number of output IEC jumpers | 1 |
Ethernet LAN (RJ-45) ports | 2 |
Cabling technology | 10/100/1000Base-T(X) |
Battery technology | Sealed Lead Acid (VRLA) |
Battery voltage | 12 V |
Battery life (max) | 5 year(s) |
Battery recharge time | 8 h |
Automatic battery test | Y |
Form factor | Tower |
Cable length | 1.5 m |
Product colour | Black |
LED indicators | Battery replacement |
International Protection (IP) code | IP20 |
Certification | CE, EAC, EN/IEC 62040-1 |
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Storage relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 3000 m |
Non-operating altitude | 0 - 3000 m |
Sustainability certificates | RoHS |
Width | 98 mm |
Depth | 310 mm |
Height | 138 mm |
Weight | 4.2 kg |
Package width | 142 mm |
Package depth | 346 mm |
Package height | 222 mm |
Package weight | 4.5 kg |
Harmonized System (HS) code | 85078000 |